hwf2v-com manual

The HWF2V-COM is a commercial fire alarm communicator offering both LTE cellular and IP connectivity. It provides single or dual path reporting to any Fire Alarm Control Panel (FACP) with a built-in dialer utilizing Contact ID format. This device ensures reliable alarm signal transmission via Verizon LTE networks and internet protocol.

Overview of HWF2V-COM Functionality

The HWF2V-COM operates as a versatile fire alarm communicator‚ designed for both single and dual-path communication. It utilizes LTE cellular via Verizon and internet protocol (IP) for sending alarm signals. The device supports Contact ID reporting‚ enabling seamless integration with any FACP that has a built-in dialer. Its primary function is to transmit alarm events to a central monitoring station through selectable reporting paths‚ ensuring reliable and redundant communication. The HWF2V-COM also includes functionalities for remote programming via AlarmNet 360. It offers three selectable reporting paths⁚ LTE cellular only‚ IP only or IP primary with LTE cellular backup.

HWF2V-COM Technical Specifications

The HWF2V-COM uses Verizon LTE cellular and IP networks for communication. It offers single or dual-path reporting with Contact ID format compatibility. The device is designed for commercial fire alarm systems and supports remote programming.

LTE/IP Communication Capabilities

The HWF2V-COM utilizes both LTE cellular and IP network paths for robust alarm communication. It supports primary IP with LTE cellular backup or LTE only reporting. This dual-path functionality ensures reliable signal transmission to the AlarmNet Network Control Center. The device offers three selectable reporting paths‚ optimizing connectivity based on the installation environment. It uses Verizon’s LTE network‚ providing broad coverage and high-speed data transfer. This facilitates efficient and dependable alarm signal delivery. IP connectivity allows for internet-based communication.

Contact ID Reporting

The HWF2V-COM is designed to provide Contact ID reporting functionality. This allows it to communicate with any Fire Alarm Control Panel (FACP) that has a built-in dialer. It transmits alarm signals using the standard Contact ID protocol. This enables seamless integration with a wide range of fire alarm systems. The Contact ID format ensures compatibility and reliable communication between the HWF2V-COM and the central monitoring station. This standard reporting method delivers detailed alarm information. This includes specific event codes for accurate alarm handling.

Installation and Setup

Proper installation involves mounting the HWF2V-COM securely to the wall‚ using screws or bolts. Wiring connections must be made according to the provided diagrams. This includes power input wires and connections to the fire panel.

Mounting the HWF2V-COM Unit

To begin‚ carefully remove the necessary knockouts from the HWF2V-COM cabinet to accommodate both power input wires and the wiring that will connect to the fire alarm panel. Next‚ securely mount the cabinet to the wall using four appropriately sized screws or bolts‚ ensuring a stable and reliable installation. Refer to the manual’s diagrams for specific details regarding knockout locations and recommended mounting hardware. Proper mounting is crucial for the device’s optimal operation and longevity. Ensure the unit is level and firmly attached to the surface.

Wiring Connections

When establishing wiring connections for the HWF2V-COM‚ always refer to the wiring diagram located inside the back cover of the manual. This diagram provides crucial information for accurate component identification and wiring procedures. Pay close attention to the power input connections‚ ensuring proper polarity and secure terminations. Additionally‚ carefully connect the wiring to the fire panel‚ following the specific instructions for your FACP. Proper wiring is essential for the reliable transmission of alarm signals and the overall functioning of the HWF2V-COM unit. Double check all connections before powering the unit.

SIM Card Replacement

The HWF2V-COM utilizes a SIM card for cellular communication. Replacing this card requires careful attention to the steps detailed in the user manual. These instructions ensure the module functions correctly post-replacement.

Steps for Replacing the SIM Card

When replacing the SIM card in the HWF2V-COM module‚ it’s crucial to follow the precise instructions outlined in the user manual. This process generally involves powering down the device‚ accessing the SIM card slot‚ and carefully removing the old card. Insert the new SIM card‚ ensuring it is properly seated. Finally‚ power the device back on and verify that the cellular connection is active. Though the process is similar to other modules‚ always consult the HWF2V-COM manual for specific details.

Software and Firmware

The HWF2V-COM’s performance is dictated by its software and firmware. Regular updates are essential for optimal operation and security. AlarmNet 360 is the platform used for programming and managing the device.

Firmware Updates

Maintaining the latest firmware on your HWF2V-COM is crucial for optimal performance and security. Firmware updates address software anomalies and improve overall system stability. It is essential to verify that the HWF2V-COM firmware is version 3.0.7 or greater to utilize AlarmNet 360 programming features. For units operating with firmware version 3.2.14 or lower‚ an upgrade is mandatory to ensure compatibility and access to the latest features and security protocols. These updates are critical for the reliable operation of the fire alarm communication system.

AlarmNet 360 Programming

The HWF2V-COM utilizes AlarmNet 360 for its programming and configuration. To begin‚ ensure that your HWF2V-COM device has firmware version 3.0.7 or higher. Access the AlarmNet 360 platform by logging in with your credentials. This platform enables you to program the communicator and set up the required parameters for your specific installation. This includes configuring the reporting paths‚ setting up the contact ID information and managing various settings for optimal communication with the monitoring center. Proper programming is essential for reliable fire alarm signal transmission.

Troubleshooting

Software anomalies might affect HWF2V-COM communicators. Refer to MyWebTech Technical Notification 49 for troubleshooting steps. Addressing these issues ensures the device operates correctly and reliably‚ and maintains communication.

Addressing Software Anomalies

A known software anomaly has been identified in the Resideo HWF2V-COM communicators. This issue may impact the device’s performance. To address this‚ consult MyWebTech Technical Notification 49. This notification provides specific troubleshooting steps to follow if your communicator is affected. It is crucial to verify that your HWF2V-COM firmware is updated to the latest version. Following the instructions in the notification will ensure optimal operation and reliability of the communicator.

Accessories and Components

Essential accessories include the CELL-ANT3DB antenna and 7626-50HC antenna cable for remote installations. A handheld programmer‚ model 7720P‚ and a plug-in transformer box‚ HPTCOVER‚ are also available for convenient setup and maintenance.

Antennas and Cables

The CELL-ANT3DB antenna‚ a 3dBA gain antenna‚ is a crucial component for ensuring optimal cellular signal reception for the HWF2V-COM. For remote antenna installations‚ the 7626-50HC antenna cable is required‚ allowing flexible placement of the antenna to maximize signal strength. Proper installation of these components ensures reliable communication with the Verizon LTE network. These external hardware elements are essential for proper functioning and signal quality of the HWF2V-COM system‚ especially in areas with weaker cellular signals and are designed for ease of use.

Handheld Programmers

The 7720P handheld programmer is a vital accessory for the HWF2V-COM‚ HWF2A-COM‚ and IPGSM-4G communication modules. This device facilitates easy configuration and programming of these units‚ streamlining the setup process. The handheld programmer allows technicians to quickly adjust settings‚ verify connections‚ and perform diagnostic checks on the fire alarm communicators without the need for a computer. Its portability and user-friendly interface make it an essential tool for installers‚ ensuring efficient and accurate programming in the field‚ and allows for quick adjustments.

Compatibility

The HWF2V-COM is designed to be compatible with any Fire Alarm Control Panel (FACP) that features a built-in dialer. This ensures seamless integration and reliable Contact ID reporting for a wide range of systems.

FACP Compatibility

The HWF2V-COM communicator is engineered for broad compatibility with various Fire Alarm Control Panels (FACPs). It supports any FACP that includes a built-in dialer‚ enabling seamless integration and reliable transmission of alarm signals via Contact ID reporting. This versatility ensures that the HWF2V-COM can be easily incorporated into existing fire alarm systems without requiring significant modifications to the FACP. The communicator’s design prioritizes interoperability‚ allowing for flexible deployment across diverse fire safety installations‚ making it a suitable choice for numerous commercial settings.

Certifications

The HWF2V-COM is compliant with FDNY requirements‚ ensuring it meets stringent standards for fire alarm communication systems. This certification validates its reliability and suitability for use in New York City.

FDNY Compliance

The HWF2V-COM is designed to meet the specific requirements of the Fire Department of New York (FDNY) for fire alarm communication. To achieve FDNY compliance‚ the HWF2V-COM must be configured to ensure five-minute fault annunciation. This involves specific settings and programming to guarantee that any communication failures are promptly reported within the specified timeframe. Meeting these FDNY standards is crucial for installations within New York City‚ ensuring life safety and regulatory adherence.

Additional Resources

For comprehensive information‚ the user manual for the HWF2V-COM is available online. This manual provides detailed instructions on installation‚ setup‚ and troubleshooting‚ ensuring proper operation of the device.

Accessing the User Manual

The complete user manual for the HWF2V-COM is readily available for online viewing and download in PDF format. This document provides detailed installation instructions‚ wiring diagrams‚ and setup procedures. It includes troubleshooting tips and essential technical specifications. Accessing the manual ensures users have all necessary information for proper installation‚ configuration‚ and maintenance. The manual serves as a comprehensive guide for understanding all aspects of the HWF2V-COM‚ from initial setup to ongoing operation‚ making it an invaluable resource for users.